Proper roof venting is critical to good
construction practices and maintenance. The purpose of roof venting is to
reduce temperature build-up inside the roof cavity during the summer months
and to reduce fungal wood rot and other problems associated with
condensation in the roof cavity during the cooler months of the year.

A good venting system, using our
Regular Series Vents, allows for a continuous
flow of air which enters the roof cavity at a low spot in the roof (for
example, under the eave) and exits the roof at a high spot (for example, at
or near the ridge of the roof). As a general rule, there is no need to
provide for any sort of mechanical assistance, fans, or other devices to the
roof venting system. A good venting system works adequately by means of a
natural convection current where warm air rises and pulls the cooler, drier
air behind it. A good roof venting system must also be designed in such a
way as to provide for proper air flow at all portions of the roof.
Improperly vented roofs often result in
premature deterioration of the roofing material and fungal wood rot in the
roof framing and sheathing. It is not uncommon to find an improperly vented
fifteen-year-old roof with badly curled (and thus non-functional) roofing
material and advanced fungal wood rot on the lower side of the roof
sheathing. With the introduction of more insulation and weather sealing, as
well as other building techniques which reduce venting, proper roof venting
techniques are even more critical than in the past.
How many Regular Series Vents would you need
for your roof system? Below is example calculations based on our 3" and 4"
Regular Series Vents.
3" Regular Series Vents with
no vapor barrier
((2100sq.ft./150)x12)/1.77sq.in.=95, 3"
Regular Series Vents |
3" Regular Series Vents with
vapor barrier
((2100sq.ft./300)x12)/1.77sq.in.=47, 3"
Regular Series Vents |
4" Regular Series Vents with
no vapor barrier
((2100sq.ft./150)x12)/2.85sq.in.=59, 4"
Regular Series Vents |
4" Regular Series Vents with
vapor barrier
((2100sq.ft./300)x12)/2.85sq.in.=29, 4"